| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : GFUVE
Model Number : P50-3
Certification : CE UL
Place of Origin : China
Price : Negotiable
MOQ : 1
Payment Terms : T/T, Western Union, L/C
Supply Ability : 5000 pieces per month
Delivery Time : Within 7 Days
Packaging Details : Export Carton Box
Ratio : 1000: 1 (customized)
Accuracy : 0.2%
Primary current : 0 - 1000A AC
Secondary output : 5mV/A
Output signal : 1V,2V,5V AC at nominal input current or customized
Frequency range : 40Hz-2000Hz
Dielectric strength : 3KV 50Hz/60Hz at 1 minute
Temperature range : -20°C to +55°C
Name : 1000A Clamp On Current Transformer
Application : Electronics power quality analyzer
 
 
 P50-3 Electronics power quality analyzer 1000A Clamp On Current Transformer Amp Clamp 40Hz - 2000Hz For Voltage Output
  
 Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured.
  
 The GFUVE AC-only Current Sensor P50-3 apply current measurement for direct readings on DMM's, loggers, Best-in-class bandwidth up to 200mHz. They are built to the latest safety and performance standards, and carry the CE mark.
  
 GFUVE Clamp-on Current Transformer are designed for fast and easy installation.Clamp-on Current Transformer uses Permalloy magnetic core or Silicon and amorphous core, with characteristics of small size, high precision, good stability and strong anti-interference ability.
  
 Why Choose GFUVE Current Probes. The Most Comprehensive Line of Current Probes. GFUVE ® the world's largest supplier, offers current probe models capable of accurately measuring from the low µA to kA range. A wide variety of configurations and jaw sizes are available. Probe types include iron core, Hall Effect, Flux Gate, and Rogowski etc.
  
 GFUVE Current transformer clamp meters are equipped with rigid jaws of made of ferrite iron. The jaws are individually wrapped by coils of copper wire. Together, they form a magnetic core during measurements. Their basic operation is like that of a transformer. It works with one primary turn, or winding, which in nearly all cases is the conductor .
  
  
  
 Features
  
 Measurement range of 1mA to 1200A AC
 Large jaw opening accommodates conductors up to two 500kcmil
 Improved ergonomic design and easy operation
 High content nickel metal core
 Conforms to EN 61010, 600V CAT III
 Low phase shift for power measurement
 Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
 UL, CE mark
  
  
 Applications
  
 Power quality measuring
 Large industrial loads
 Measuring around cable bundles
 Power load monitoring
 Waveform analysis
 Energy meter calibrator
  
  
 Parameter
  
| Electrical parameters | |
| Ratio | 1000: 1 or 2000:1 (customized) | 
| Accuracy class | 0.1%, 0.2%, 0.5% | 
| Primary current | 0 - 1000A AC | 
| Secondary output | 1mV/A AC, 5mV/A or (customized) | 
| Max. Cont. Input current | 1200A | 
| Over voltage category | CAT III 600V | 
| Output signal | 333mV, 500mV,1V,2V,5V AC at nominal input current | 
| Accuracy (1000A Range) | |
| 0-10A | ≤0.5% | 
| 10-100 | ≤0.2% | 
| 10-1200A | ≤0.1% | 
| Phase Shift(1000A Range) | |
| 0-10A | ≤0.5° | 
| 10-100 | ≤0.2° | 
| 100-1200A | ≤0.1° | 
| Frequency range | 40Hz-2000Hz | 
| Dielectric strength | 3KV 50Hz/60Hz at 1 minute | 
| Temperature range | -20°C to +55°C | 
| Output | 2.5 meter cable with D01 connector | 
| Max. voltage not insulated conductors | 600 V | 
| Standard | EN 61010-1, EN 61010-2-032, IEC60044-1 | 
| Installation | Clamp type | 
| Output mode | Lead output (2.5m) | 
| Mechanical parameters | |
| Dimensions (L x W x H) (mm) | 102.9 x 219.6 x 28 | 
| Weight (g) | 550 | 
| Holding wire diameter (mm) | φ50 | 
| Max. jaw opening (mm) | 50 | 
| Color | Gray or blue | 
| Material | PC+ABS+Polycarbonate, UL94 V0 | 
 
 Selection
| Model | Rate Current | Max Current | Secondary Voltage | Coil Ratio | Burden Resistance | Accuracy | 
| P50V1-1000 | 1000A | 1200A | 1V | 1000:1 | customized | 0.1% | 
| P50V2-1000 | 1000A | 1200A | 2V | 1000:1 | customized | 0.1% | 
| P50V4-1000 | 1000A | 1200A | 4V | 1000:1 | customized | 0.1% | 
| P50V5-1000 | 1000A | 1200A | 5V | 1000:1 | customized | 0.1% | 
| P50V10-1000 | 1000A | 1200A | 10V | 1000:1 | customized | 0.1% | 
| P50V1-500 | 500A | 600A | 1V | 1000:1 | customized | 0.2% | 
| P50V2-500 | 500A | 600A | 2V | 1000:1 | customized | 0.2% | 
| P50V4-500 | 500A | 600A | 4V | 1000:1 | customized | 0.2% | 
| P50V5-500 | 500A | 600A | 5V | 1000:1 | customized | 0.2% | 
| P50V10-500 | 500A | 600A | 10V | 1000:1 | customized | 0.2% | 
 
 FAQ, following questions will help you to select the matched probe for your applications.
 1. Please determine if you are measuring AC or DC?
 GFUVE P50-3 is for AC measuring. If DC, we have hall effect models to suggest.
  
 2. What is the maximum current you will measure?
 P50-3 maximum current is 1200A
  
 3. What size conductor will you clamp onto? This parameter determines the probe jaw size needed.
 P50-3 can clamp conductor diameter size is 50mm
  
 4. What type of probe output do you need or can you work with (mA, mV, A, AC, etc.)?
 P50-3 can customize output with mA, mV. A, V.
  
 5. What is the working voltage of the conductor to be measured?
 GFUVE probes should be used below 600 volts
  
 6. What type of termination do you need: jacks, leads or BNC?
 P50-3 standard has 2.5meter leads. We can offer jacks or BNC… as options.
  
 7. If you cannot find information you need or would like assistance, contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.
  
  
  
 Photos
 
  
|   | 
| Electronics power quality analyzer 1000A Clamp On Current Transformer Amp Clamp 40Hz - 2000Hz For Voltage Output Images | 
 10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw
                                                                                        
                                                        
                        
                        
                        
                                                            10M Hz Ratio 500A / 500mA AC Current Clamp On Current Transformer busbar Jaw
                                                    
                        
                     1000A/1A 0.1% Precision Oscilloscope Clamp On Current Transformer With 4mm / BNC
                                                                                        
                                                        
                        
                        
                        
                                                            1000A/1A 0.1% Precision Oscilloscope Clamp On Current Transformer With 4mm / BNC
                                                    
                        
                     1500A 2KHz Oscilloscope Clamp On Current Transformer , 0.5% Accuracy Current
                                                                                        
                                                        
                        
                        
                        
                                                            1500A 2KHz Oscilloscope Clamp On Current Transformer , 0.5% Accuracy Current
                                                    
                        
                     Clamp On Ct Current Transformer 2m Bandwidth 1000a/5a For Power Quality Analyzer
                                                                                        
                                                        
                        
                        
                        
                                                            Clamp On Ct Current Transformer 2m Bandwidth 1000a/5a For Power Quality Analyzer
                                                    
                        
                     High Linearity Clamp On Current Transformer Good Stability 550g Weight
                                                                                        
                                                        
                        
                        
                        
                                                            High Linearity Clamp On Current Transformer Good Stability 550g Weight
                                                    
                        
                     Single Phase 1000A Clamp On Current Transformer 50mm Diameter For Electronic
                                                                                        
                                                        
                        
                        
                        
                                                            Single Phase 1000A Clamp On Current Transformer 50mm Diameter For Electronic
                                                    
                        
                     Outdoor Clamp Type Current Transformer High Magnetic Conductivity For Measuremen
                                                                                        
                                                        
                        
                        
                        
                                                            Outdoor Clamp Type Current Transformer High Magnetic Conductivity For Measuremen
                                                    
                        
                     1000A/5A Clamp On Current Transformer IEC60044-1 Standard For Power Monitor
                                                                                        
                                                        
                        
                        
                        
                                                            1000A/5A Clamp On Current Transformer IEC60044-1 Standard For Power Monitor
                                                    
                        
                     Outdoor CT Clamp On Current Transformer Zero Phase AC Current Transformer P50
                                                                                        
                                                        
                        
                        
                        
                                                            Outdoor CT Clamp On Current Transformer Zero Phase AC Current Transformer P50
                                                    
                        
                     GFUVE Low Current Automotive Amp Clamp on Current Transformer Ratio 10A / 10mA
                                                                                    
                        
                        
                        
                                                            GFUVE Low Current Automotive Amp Clamp on Current Transformer Ratio 10A / 10mA