| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : GFUVE
Model Number : GF1061
Certification : CE, ISO9001
Place of Origin : BEIJING CHINA
MOQ : 1SET
Price : 25000-35000USD/SET
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 200SETS/MONTH
Delivery Time : 2-3weeks
Packaging Details : Standard Export Box
Name : CT PT analyzer
Application : current transformer and potential transformer test
Theory : DC variable-frequency methods
LCD : 7inch TFT touch color LCD
Phase error : 1min or 3min
Ratio error : 0.02% or 0.05%
CT raito : 1-50000
PT ratio : 1-10000
Usage : Measurement CT and Protection CT
0.02 Class High Precision Portable CT PT Analyzer with Printer
GF1061 portable CT PT analyzer is mainly used for field or lab testing, it can finish the measurements (M) and protection (P) class CT, PT and TYP class CT. Adopt 7 inch touch TFT LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data. The CT PT Analyzer is the most complete and easy-to-use testing system for protection and metering CTs according to IEEE and IEC standards.
The CT Analyzer automatically determines all relevant current transformer values and compares the results with the selected standard. The device evaluates the current transformer as per the IEC or IEEE standard within seconds with the push of a button. it can test current transformer and potential transformer ratio error and phase rerror, Magnetization curve etc. 
 It facilitates fast and economical on-site testing and calibration of metering and protection current transformers. Manufacturers of current transformers, high voltage transformers and switchgear also use the CT Analyzer for tests during development and production.
| I. Current Transformer (CT) | II. Voltage Transformer (PT) | 
|---|---|
| 1. Magnetization curve | 1. Excitation characteristic test | 
| 2. Transformation ratio test | 2. Transformation ratio test | 
| 3. Polarity | 3. Polarity | 
| 4. 5% and 10% error curve | 4. Ratio error, phase error | 
| 5. Accuracy limiting factor (ALF) | 5. Degauss | 
| 6. Degauss | 6. Calculation of knee point value | 
| 7. Ratio error, phase error | 7. Actual secondary load test (burden test) | 
| 8. Automatic calculation of excitation knee point value | 8. Resistance test | 
| 9. Actual secondary load test (burden test) | |
| 10. Resistance test | |
| 11. Secondary time constant (Ts) | |
| 12. Remanence coefficient (Kr) | |
| 13. Transient dimensioning factor (Ktd) | |
| 14. Peak instantaneous error (Er) | |
| 15. Magnetizing inductance (LU) | |
| 16. Instruments security factor(FS) | |
| 17. Composite error | |
| Electrical parameters | ||
|---|---|---|
| Accuracy | 0.05% | |
| Power supply | AC 220V±10% or AC 120V±10%, 50/60Hz or Battery | |
| Output voltage | 0-100Vrms | |
| Output current | 0-5Arms (20A peak-value) | |
| Output power | 0-400 VA (1500 VApeak) | |
| Automatic frequency variation range | 0.1-60Hz | |
| Equivalent excitation voltage | ≤5000V | |
| Accuracy | ≤0.5% | |
| Secondary winding DC resistance measurement | Range | 0.1-1000Ω | 
| Accuracy | ≤0.05% | |
| Secondary actual load measurement | Range | 5VA-1000VA | 
| Accuracy | ≤0.5%±0.1VA | |
| CT/PT phase error measurement | Accuracy | ±1min (typical) / 3 min (guaranteed) | 
| Resolution | 0.1min | |
| CT ratio error measurement | Range | 1-50000 | 
| Accuracy | ≤0.05% | |
| PT ratio error measurement | Range | 1-10000 | 
| Accuracy | ≤0.05% | |
| Standards | ||
| Reference standards | GB1207-2006, GB1208-2006, GB16847-1997 IEC60044-1, IEC60044-6, IEC61869-2, ANSI/IEEE C57.13 | |
| Safety standards | GB 4793.1-2007 | |
| EMC | EMC standard 89/336/EEC | |
| FCC Subpart B of Part 15 Class A | ||
| IEC 1000-4-2 /3 /4 /6 | ||
| Mechanical parameters | ||
| Overall dimension (L x W x H) (mm) | 280 x 250 x 160 | |
| Weight (kg) | ≤4 | |
| Environmental conditions | ||
| Relative humidity | Relative humidity 5%-95% not condensing | |
| Operating temperature | -10°C to +50°C | |
| Storage temperature | -20°C to +70°C | |
| Altitude | ≤1000m | |

|   | 
| High Precision Portable CT PT Analyzer 0.02% / 0.05% Ratio Error With Printer Images | 
 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing
                                                                                        
                                                        
                        
                        
                        
                                                            1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing
                                                    
                        
                     GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05
                                                                                    
                        
                        
                        
                                                            GF106 CT PT Analyzer Ct Pt Testing Equipment Type Printer Portable Accuracy 0.05
                                                    
                        
                     Automatic Smart IEC60044-1 Pt Potential Transformer
                                                                                        
                                                        
                        
                        
                        
                                                            Automatic Smart IEC60044-1 Pt Potential Transformer
                                                    
                        
                     4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy
                                                                                        
                                                        
                        
                        
                        
                                                            4.8KG Weight CT PT Analyzer Voltage Transformer Analyzer 0.02% / 0.05% Accuracy
                                                    
                        
                     Portable GFUVE CT PT Analyzer Current Transformer Testing IEC60044-1
                                                                                        
                                                        
                        
                        
                        
                                                            Portable GFUVE CT PT Analyzer Current Transformer Testing IEC60044-1
                                                    
                        
                     GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification
                                                                                        
                                                        
                        
                        
                        
                                                            GF1061 Ct Pt Analyzer Ct Pt Testing Equipment Electronic Power CE Certification
                                                    
                        
                     Electronic Power Power Quality Analyzer Portable Ct Testing Equipment 4kg Weight
                                                                                        
                                                        
                        
                        
                        
                                                            Electronic Power Power Quality Analyzer Portable Ct Testing Equipment 4kg Weight
                                                    
                        
                     Electronic Ct Test Equipment High Precision GF1061 Easy Operation For Lab
                                                                                        
                                                        
                        
                        
                        
                                                            Electronic Ct Test Equipment High Precision GF1061 Easy Operation For Lab
                                                    
                        
                     Portable Potential Current Transformer Testing Equipments With Ct Test Function
                                                                                        
                                                        
                        
                        
                        
                                                            Portable Potential Current Transformer Testing Equipments With Ct Test Function
                                                    
                        
                     Portable Voltage PT Power Transformer Testing Equipment With Polarity 4.8KG
                                                                                        
                                                        
                        
                        
                        
                                                            Portable Voltage PT Power Transformer Testing Equipment With Polarity 4.8KG