| Sign In | Join Free | My benadorassociates.com | 
 | 
Brand Name : GFUVE
Model Number : LZCK350-10
Certification : CE, UL, ISO9001
Place of Origin : BEIJING CHINA
MOQ : 3 PCS
Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability : 50000 PCS/MONTH
Delivery Time : 3-7 days
Packaging Details : Standard Export Box
Name : 100 / 5A Split Core Current Transformer Dry Type
Aperture : 50mm
Rated load : ≤ 25VA
Ratio : 100-1000A/5A or 1A
Accuracy : 0.5%
Color : Red & Black
100 / 5A Split Core Current Transformer Dry Type
Introduction
The most common usage of current transformers is to operate instruments or metering from high voltage or high current circuits, safely isolating secondary control circuitry from the high voltages or currents. The primary winding of the transformer is connected to the high voltage or high current circuit, and the meter or relay is connected to the secondary circuit. Installation With electricity, suite for power monitor, energy loss etc.
Split core current transformers may also be used as an isolation instrument transformer so that secondary quantities may be used in phase shifting without affecting other primary connected devices.
Applications
 LZCK322-10 split core current transformer is suitable forcurrent measurement and microcomputer protection of electrical equipment in 10KV and 35KV AC power system.It is widely used in compact fully insulated ring network switchgears such as ABB-Safe Ring/Safe Plus...and cable distribution boxes.The transformer can be directly installed at the inlet andoutlet cables.The slice is imported silicon material. Thesemicircular ring core and secondary windings arevacuum poured by insulated resin.
  
Features
 The semicircular ring core and secondary windings are vacuum poured by high quality epoxide resin in the fire retardant plastic casing, which has the characteristic of moisture proof, stable performance and dispensing with maintenance.Small size, light weight, small footprint, fixed in the ring network switchgear cable.The cable can cross the current transformer through its internal poles quickly and uniformly.
 The Cast Resin Straight-Through Current Transformer can be divided several kinds according to the various current ratio, accuracy and rated loads. The specific parameters are showed in the corresponding to each model parameter tables.
  
PARAMETERS
| Technical parameters | |
|---|---|
| Standards | IEC60044-1; IEC 61869-2; NTC 2205; GB1208-2006; ANSI C57.13 | 
| Accuracy Class | 0.5S, 0.5%, 1%, 3% | 
| Range of primary rated current | 100-1500A | 
| Range of Rated load | ≤10VA | 
| Rated frequency | 50/60Hz | 
| Rated secondary current | 5A or 1A | 
| Rated short-time thermal current | 40kA, 1S | 
| Rated continuous thermal current | 150%I1n | 
| Secondary winding power frequency withstand voltage | 3kV, 1min | 
| Safety Factor Rating | (FS) <10 | 
| Output signal | 1A, 5A, 333mV, 1V or 5V(customized) | 
| Cable length | 2.5m, 5m, 10m(customized) | 
| Flame retardant ABS plastic shell inside, jaw waterproof apron. | |
| Mechanical parameters | |
| Aperture (mm) | Φ55 | 
| Dimensions (W×D×H) (mm) | 180×138×52 | 
| Weight (kg) | 2 | 
| Working conditions | |
| Operating temperature | -35°C to +65°C, not exceeding +40°C | 
| Storage temperature | -40°C to +70°C | 
| Ingress Protection | IP65 | 
| Environment | outdoors or indoors | 
| The Height of above sea level | 0- 3000m | 
| Conditions | No existence of severely begrimed, erosive and radioactive gas in the air. Continuous working under the rated current is allowed. | 
SELECTION GUIDE
| Technical parameters | |
|---|---|
| Standards | IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 | 
| Rated primary current | 30-600A | 
| Rated load | ≤10VA | 
| Rated frequency | 50Hz or 60Hz | 
| Rated secondary current | 5A or 1A | 
| Rated short-time thermal current | 40kA, 1S | 
| Rated continuous thermal current | 120%I1n | 
| Secondary winding power-frequency voltage | 3kV, 1min | 
| Instrument security factor | FS≤10 | 
| Mechanical parameters | |
| Dimensions (W×D×H) (mm) | φ50xφ110x52 | 
| Weight (kg) | 1.6 | 
| Operating conditions | |
| Operating temperature | -35°C to +55°C | 
| Daily average temp | <+40°C | 
| Altitude | <3500 meters | 
| Condition | No existence of severely begrimed, erosive and radioactive gas in the air. Permission of long-term operation under rated current. | 
TECHNICAL DATA
| Type | LZCK322-10 | LZCK322-10 | ||||
|---|---|---|---|---|---|---|
| Purpose | Measuring current transformer | Protection current transformer | ||||
| Ratio | Accuracy class and rated load(VA) | Accuracy class and rated load(VA) | ||||
| I1/I2 | 0.5 | 1 | 3 | 10P15 | 10P10 | 10P5 | 
| 30/1 | 1 | 1.5 | ||||
| 50/1 | 1 | 2 | 1.25 | |||
| 75/1 | 1.5 | 2.5 | 1 | 2 | ||
| 100/1 | 2 | 2.5 | 3 | 1.5 | 2.5 | |
| 200/1 | 2.5 | 1.25 | 2.5 | |||
| 300/1 | 3.75 | 1.25 | 2.5 | |||
| 400/1 | 7.5 | 1.25 | 2.5 | |||
| 500/1 | 10 | 1.25 | 3 | |||
| 600/1 | 10 | 1.5 | 3 | |||
| 50/5 | 2.5 | |||||
| 75/5 | 2.5 | |||||
| 100/5 | 2.5 | |||||
| 200/5 | 3.75 | |||||
| 300/5 | 5 | |||||
| 400/5 | 7.5 | 2.5 | ||||
| 500/5 | 7.5 | 2.5 | ||||
| 600/5 | 10 | 3.75 | ||||
SELECTION GUIDE
| Model | Primary rated current | Rated load | Aperture (mm) | Description (mm) | Weight (kg) | Material | Water-proof | 
|---|---|---|---|---|---|---|---|
| LZCK-55 | 100-1500A | ≤10VA | φ55 | 180×138×52 | 2 | PC | IP65 | 
| LMCK185-10 | 300-3000A | ≤25VA | φ185 | 350×283×55 | 4.5 | PC | IP65 | 
| LZCK310-10 | 300-600A | ≤10VA | φ50 | φ50 x φ110 x 32 | 1 | Resin | silicon case (option) | 
| LZCK322-10 | 30-600A | ≤10VA | φ50 | φ50 x φ110 x 52 | 1.6 | Resin | silicon case (option) | 
| LZCK350-10 | 20-600A | ≤25VA | φ50 | φ50 x φ110 x 105 | 3.1 | Resin | silicon case (option) | 
| LZCG530-10 | 30-600A | ≤20VA | φ45 | φ45 x φ120 x 65 | 2.1 | Resin | silicon case (option) | 
Wiring diagrams
P1, P2 is primary polarity terminal, S1, S2 is secondary polarity terminal.
 P2, S2 is homonymous terminals (subtractive polarity).
ORDERING INFORMATION
Be sure to the type, current ratio, accuracy class, rated load and use of the products when you plan to make a order. Special specifications could be customized.All kinds of different specifications and parameters current transformers can be made according to your needs.
Product Photo

|   | 
| 100 / 5A Core Balance Current Transformer Dry Type 50mm Aperture 0.5% High Accuracy Images | 
 4mm Banana Connector 1000A/5A Split Core Current Transformer With 110mm & 50m
                                                                                    
                        
                        
                        
                                                            4mm Banana Connector 1000A/5A Split Core Current Transformer With 110mm & 50m
                                                    
                        
                     IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric
                                                                                    
                        
                        
                        
                                                            IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric
                                                    
                        
                     ABS Cover Split Core Current Transformer CT 2.5VA Burden 0.5% High Accuracy
                                                                                    
                        
                        
                        
                                                            ABS Cover Split Core Current Transformer CT 2.5VA Burden 0.5% High Accuracy
                                                    
                        
                     FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power
                                                                                    
                        
                        
                        
                                                            FU16 333mv Mini Dual Core Current Transformer Low Phase Shift For Power
                                                    
                        
                     200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0
                                                                                    
                        
                        
                        
                                                            200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0
                                                    
                        
                     Resin Cast Split Core Current Transformer 600/5A Network Switchgears Application
                                                                                    
                        
                        
                        
                                                            Resin Cast Split Core Current Transformer 600/5A Network Switchgears Application
                                                    
                        
                     GFUVE 100A / 5A Split Core Clamp On Current Transformer IP67 Outdoor Installatio
                                                                                        
                                                        
                        
                        
                        
                                                            GFUVE 100A / 5A Split Core Clamp On Current Transformer IP67 Outdoor Installatio
                                                    
                        
                     50Hz / 60Hz Split Core Current Transformer Epoxy Resin Cast CT 3.1 Kgs Weight
                                                                                    
                        
                        
                        
                                                            50Hz / 60Hz Split Core Current Transformer Epoxy Resin Cast CT 3.1 Kgs Weight
                                                    
                        
                     400kv Class 1 Ring Core Current Transformer Mini Current Transformer Compact
                                                                                    
                        
                        
                        
                                                            400kv Class 1 Ring Core Current Transformer Mini Current Transformer Compact
                                                    
                        
                     Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage
                                                                                    
                        
                        
                        
                                                            Outdoor Waterproof Split Core Current Transducer 1500A Medium Voltage